Forums › General Discussions › EMC – automatic scanning of results provided in the Peak Table
- This topic has 2 replies, 2 voices, and was last updated 2 days, 1 hour ago by
miran.
- AuthorPosts

miranParticipantHi
A solution that enables automatic scanning of results provided in the Peak Table (via Spike 4.0.13 Analysis Mode -> EMC precompliance -> Peak Table -> Actions -> Scan) is highly useful, as it eliminates the need to manually select multiple results, transfer them to Meter Settings for Quasi-Peak (QP) detector measurements, and then manually add them back to the list.Unfortunately, the Spike software consistently crashes when choosing ‘Scan’ from the Peak Table -> Actions menu. I have tested this on multiple computers, and the program routinely crashes on all of them. Are you aware of this issue?
I would appreciate it if you could test this functionality on your end and include a fix in the next software release.
Thank you very much
Best regards Miran
AndrewModerator- This reply was modified 2 days, 1 hour ago by
Andrew.
Hi Miran,
I can reproduce. It looks like this issue was introduced in the most recent version. I already have a fix and it should go out in a release next week. I apologize for the inconvenience.
Here’s a link to the previous version if you want a version that should not contain this bug. You will need to uninstall the newer version manually before installing.
https://signalhound.com/sigdownloads/Spike/Spike(x64)_4_0_12.zip
Thanks as always.

miranParticipantHello
Thank you very much for your quick response and confirmation of the problem. Best regards from Slovenia- This reply was modified 2 days, 1 hour ago by
- AuthorPosts