Forums › BB Series Discussions › Changing center freq in iq capturing
- This topic has 2 replies, 3 voices, and was last updated 3 years ago by KE5FX. 
- AuthorPosts
 JGengParticipant- Hello, - I’m acquiring IQ data using bbGetIQUnpacked API. 
 I was hoping to hopping from one frequency to another, do I have to reconfigure using bb_configure_IQ_center and then reinitiate again?
 That takes about couple ms and I’m hoping not having a large gap when switching frequency.
 Thanks.- Bests, 
 Jing 
 AndrewModerator- Hi Jing, - Yes, you have to reconfigure the receiver between I/Q captures, and yes, with the BB60, there will always be a gap when switching frequencies. I would expect the gap to be in the 10’s of milliseconds. - Unfortunately there is not a way to improve this with the BB60. Our SM200/435 has an I/Q sweep list feature, which allows for preconfigured I/Q frequency/capture_len pairs to allow for very fast switching times, (120us switch times). I can provide more information on that if desired. - Andrew 
 KE5FXParticipant- How far apart are the frequencies you need to switch between? Maybe you could do it yourself with a “second conversion” in software. 
- AuthorPosts